LEGRAND MEGALINE RACK

SPHINX i Europa
DK
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgrupper > USV (UPS) > LEGRAND MEGALINE RACK

LEGRAND MEGALINE RACK

Single-phase modular UPS systems from 1.25 to 10 kVA

LEGRAND MEGALINE RACK
5961_18700.png
5961_18701.jpg
5961_18702.jpg
5961_18703.jpg
5961_18704.jpg
5961_18705.jpg
  • egenskaberegenskaber
  • beskrivelsebeskrivelse
  • yderligere informationyderligere information
  • PDFPDF
  • Single-phase modular UPS systems (19” rack)
  • Power from 1250 to 5000 VA
  • VFI-111 on-line double conversion
  • Adaptable, expandable and redundant solutions
  • Easy and fast management and maintenance

MEGALINE RACK UPS is a single phase uninterruptible power supply with high frequency PWM technology, On Line Double Conversion type, modular architecture, with the possibility of N+X redundant configuration, for 19” rack cabinet.

It delivers a rated power from 1250 to 5000VA, equipped with valve-regulated hermetic-type accumulator batteries, contained inside the UPS in a specific compartment or in one or more external cabinets.


Functions

  • Wide voltage range and input frequency
  • Operating frequency from 50 to 60 Hz with auto-recognition
  • Frequency conversion 50 in – 60 out or vice versa
  • Extension of the input frequency range for operation with power-supply units
  • Operation in eco mode (energy-saving)
  • Possibility to set on line mode with a minimum load rate
  • Adjustable output voltage with 1V intervals from front panel
  • Low level of noise
  • Measures internal and external temperature
  • Controls the ventilation in relation to the temperature and the load
  • Designed for remote emergency switch-off
ProdGrafik

Characteristics



General characteristics 3 103 34
3 103 38
3 103 79
3 103 35
3 103 39
3 103 81
3 103 36
3 103 40
3 103 83
3 103 37
3 103 41
3 103 85
Nominal power (VA) 1250 2500 3750 5000
Active power (W) 875 1750 2625 3500
Max. expansion (VA) 5000
Max. expansion (W) 3500
Technology On-line double conversion VFI-SS-111
Architecture Modular, expandable, N+X redundant with 1250 VA power cards,contained in a single Modular, expandable, N+X redundant with 1250 VA power cards,
contained in a single rack
Input characteristics
Nominal input voltage 230 V
Input voltage range 184 V to 264 V at 100% load
Minimum operating voltage 100 V at 50% load
THD of input current < 3%
Input power factor > 0.99 at 20% load
Input frequency 50 Hz/60 Hz ± 2% autosensing
Output characteristics
Output voltage 230 V ± 1%
Output frequency 50 Hz/60 Hz synchronised
THD of output voltage < 1% with non-linear load
Waveform Sinusoidal
Peak factor 1:3
Efficiency up to 92%
Overload capacity 300% for 1 s – 200% for 5 s – 150% for 30 s
Backup time
Backup time (min) 13
Extension of backup time Yes
Equipment
Bypass Automatic, internally synchronised, static and electromechanical
(for overloads and operating problems)
Signalling and alarms Large screen with 4 alphanumeric lines, multi-coloured status indicator,
audible signalling
Communication ports 1 RS 232 port, 2 logic level ports
Communicator UPS software Can be downloaded free of charge (after requesting an activation code)
Protection Electronic devices for protection against overloads, short-circuits and excessive battery discharge.
Operation stops at end of backup time. Inrush current limiter on start-up.
Sensor for correct neutral switching.
Back-feed protection (electrical safety insulation of the input plug during battery-based operation).
EPO (emergency power off) contact.
I/O mains connection German standard/terminal connector with universal multi-socket outlet (Italian/German standard)
Mechanical characteristics
Net weight (kg) 23,5 34 43 53
Dimensions
W x H x D (mm)
266 x 483 x 582
Installed power cards 1 2 3 4
Free power expansion slots 3 2 1 -
Installed battery kits 1 2 3 4
Free backup time extension slots 3 2 1 -
Ambient conditions
Ambient operating
temperature (°C)
0 to 40°C
Protection index IP 21
Relative humidity (%) 20 to 80%
Noise at 1 m (dBA) < 40
Certifications
Reference product
standards
EN 62040-1, EN 62040-2, EN 62040-3






ORDERING INFORMATIONS


Avaibles Modules
RACKs (German standard)
Cat. No. Nominal power (VA) Active power (W) Back-up time (min) Number of cabinets Weight (kg)
3 103 79 1250 875 13 1 23,5
3 103 81 2500 1750 13 1 34
3 103 83 3750 2625 13 1 43
3 103 85 5000 3500 13 1 53




Avaibles Modules
RACKs (French standard)
Cat. No. Nominal power (VA) Active power (W) Back-up time (min) Number of cabinets Weight (kg)
3 103 34 1250 875 13 1 23.5
3 103 35 2500 1750 13 1 34
3 103 36 3750 2625 13 1 43
3 103 37 5000 3500 13 1 53




Avaibles Modules
RACKS (British standard)
Cat. No. Nominal power (VA) Active power (W) Back-up time (min) Number of cabinets Weight (kg)
3 103 38 1250 875 13 1 23.5
3 103 39 2500 1750 13 1 34
3 103 40 3750 2625 13 1 43
3 103 41 5000 3500 13 1 53




Avaibles Modules
RACKS - without batteries
Cat. No. Nominal power (VA) Active power (W) Back-up time (min) Number of cabinets
3 103 80 1250 875 - 1
3 103 82 2500 1750 - 1
3 103 84 3750 2625 - 1
3 103 86 5000 3500 - 1