Advantech BB-WDR-120 Series

120W, Single Output, Industrial DIN Rail Power Supply

Advantech BB-WDR-120 Series
5997_18871.png
5997_18872.jpg
  • egenskaberegenskaber
  • beskrivelsebeskrivelse
  • yderligere informationyderligere information
  • PDFPDF
  • Single and two phase wide input range 180 ~ 550VAC
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL508(industrial control equipment)approved
  • EN61000-6-2(EN50082-2) industrial immunity level
  • 100% full load burn-in test
  • Built-in DC OK relay contact
120W, Single Output, Industrial DIN Rail Power Supply
ProdGrafik

SPECIFICATIONS

MODEL BB-WDR-120-12 BB-WDR-120-24
OUTPUT
DC VOLTAGE 12V 24V
RATED CURRENT 10A 5A
CURRENT RANGE 0 ~ 10A 0 ~ 5A
RATED POWER 120W 120W
RIPPLE & NOISE (max.) Note.2 120mVp-p 120mVp-p
VOLTAGE ADJ. RANGE 12 ~ 15V 24 ~ 29V
VOLTAGE TOLERANCE Note.3 ± 1.5% ± 1.0%
LINE REGULATION ± 0.5% ± 0.5%
LOAD REGULATION ± 0.5% ± 0.5%
SETUP, RISE, HOLD UP TIME 2000ms, 70ms, 50ms/400VAC        2000ms, 70ms, 10ms/230VAC at full load
INPUT
VOLTAGE RANGE 180 ~ 550VAC        254 ~ 780VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 89.5% / 400V 91% / 400V
AC CURRENT 0.7A/400VAC         1.2A/230VAC
INRUSH CURRENT (max.) COLD START 50A
LEAKAGE CURRENT <3.5mA / 530VAC
PROTECTION
OVERLOAD 105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 16 ~ 18V 31 ~ 37V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
DC OK SIGNAL Relay contact rating(max.) : 30V / 1A resistive
ENVIRONMENT
WORKING TEMP. -25 ~ +70 °C (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85 °C, 10 ~ 95% RH
TEMP. COEFFICIENT ± 0.03%/ °C (0 ~ 50°C)
VIBRATION Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
SAFETY STANDARDS Ul508 approved, IEC60950-1 CB approved by SIQ, design refer to GL;(meet EN60204-1)
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 °C/ 70% RH
EMC EMISSION Compliance to EN55011 (CISPR11), EN55032 (CISPR32), EN61204-3 Class B
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
OTHERS
MTBF 268K hrs min. MIL-HDBK-217F (25 °C)
DIMENSION 40*125.2*113.5mm (W*H*D)
PACKING 0.65Kg; 20pcs/14Kg/1.16CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25 °C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quick may lead to increase of the set up time.




ORDERING INFORMATION

Available Modules
BB-WDR-120-12 PS, DIN, WIDE VOLTAGE INPUT, 120W, 12V
BB-WDR-120-24 120W, 24V, 10A, Single Output, Industrial DIN Rail Power Supply